<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-01 08-04-50
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 51 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 70 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 19012 0,6101
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,6 dBr 3,24 dBr 4,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 8:04, 1.05.2026
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 0,6101 Acquired: 2026/05/01 8.03.45 Total samples: 19012 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 4,8 dBr MIN: 0,6 dBr AVE: 3,24 dBr % above 12,2 dBr: 0,0 Last value: 4,7 dBr (2026/05/01 8.03.45) 07.50 07.52 07.54 07.56 07.58 08.00 08.02 0 2 4 Pm [dBr]